LoadDefaultBmcCfg
Resets the BMC configuration of the managed system to factory defaults.
Syntax
OOB and In-Band
sum [-i <IP or host name> -u <username> -p <password>] -c LoadDefaultBmcCfg [--preserve_user_cfg] [--clear_user_cfg [--load_unique_password | --load_default_password]]
Remote In-Band
sum -I Remote_INB --oi <OS IP address> --ou <OS username> [--op <OS password> | --os_key <OS private key> --os_key_pw <OS private key password>] -c LoadDefaultBmcCfg [--preserve_user_cfg] [--clear_user_cfg [--load_unique_password | --load_default_password]] [--remote_sum <remote sum path>]
Options
--preserve_user_cfg: Preserves user configuration (network, users info, FRU, ADMIN password).--clear_user_cfg: Clears user configuration.--load_unique_password: Loads unique pre-programmed password (only for systems with BMC unique password).--load_default_password: Loads default "ADMIN" password.--reboot: Forces the managed system to reboot (in-band only).
Reset Behavior
| Option | Network Reset | Users Info Reset | FRU Reset | ADMIN Password |
|---|---|---|---|---|
--preserve_user_cfg |
No | No | No | Preserved |
--clear_user_cfg --load_default_password |
No | Yes | No | ADMIN |
--clear_user_cfg --load_unique_password |
No | Yes | No | Unique Password |
Examples
OOB Preserve User Config
[SUM_HOME]# ./sum -i 192.168.34.56 -u ADMIN -p PASSWORD -c LoadDefaultBmcCfg --preserve_user_cfg
OOB Clear User Config with Unique Password
[SUM_HOME]# ./sum -i 192.168.34.56 -u ADMIN -p PASSWORD -c LoadDefaultBmcCfg --clear_user_cfg --load_unique_password
OOB Clear User Config with Default Password
[SUM_HOME]# ./sum -i 192.168.34.56 -u ADMIN -p PASSWORD -c LoadDefaultBmcCfg --clear_user_cfg --load_default_password
In-Band Preserve User Config
[SUM_HOME]# ./sum -c LoadDefaultBmcCfg --preserve_user_cfg [--reboot]
In-Band Clear User Config with Unique Password
[SUM_HOME]# ./sum -c LoadDefaultBmcCfg --clear_user_cfg --load_unique_password [--reboot]
In-Band Clear User Config with Default Password
[SUM_HOME]# ./sum -c LoadDefaultBmcCfg --clear_user_cfg --load_default_password [--reboot]
Remote In-Band Preserve User Config
[SUM_HOME]# ./sum -I Remote_INB --oi 192.168.34.56 --ou root --op 111111 -c LoadDefaultBmcCfg --preserve_user_cfg [--reboot]
Notes
- The --load_unique_password option only supports systems installed with a BMC unique password.
- This command will not reset any network settings.
- Allowed option combinations depend on the managed system state. Unsupported option combinations will be denied.
- All new X10, X11, X12, H11, H12, and future generation Supermicro products ship with a "Unique Pre-Programmed Password" instead of the default "ADMIN" password.